Findings

CVE-2018-14558

Tenda AC7, AC9, and AC10 Routers Command Injection Vulnerability

Published Oct 30, 2018 · corrected/updated Jun 16, 2026 · tenda ac7 firmware · evidence confidence very high

An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the "formsetUsbUnload" function executes a dosystemCmd function with untrusted input.

Grounded briefings

Catalog interpretations for three audiences. Each brief cites ingested metadata and the original advisories below. They are not independent research and they do not invent exploit steps.

Executive

CVE-2018-14558 is a critical public vulnerability record for tenda ac7 firmware. CISA lists it as known exploited. Published remediation guidance: Apply updates per vendor instructions. This summary is a catalog interpretation of the ingested metadata and cites the original advisories below.

System administrator

Identify whether tenda ac7 firmware is in your estate, then compare installed versions with the affected ranges. Affected packages or ranges on record: tenda/ac10 firmware; tenda/ac7 firmware; tenda/ac9 firmware; Tenda AC7, AC9, and AC10 Routers. Published remediation guidance: Apply updates per vendor instructions. Prefer the vendor or distribution advisory linked in Sources before changing production systems. This is a catalog interpretation, not a runbook.

Security analyst

Signals on file: CVSS 9.8, EPSS 8.5%. CISA lists it as known exploited. Weakness classes: CWE-78. Sources contributing to this record: cisa_kev, cve_org, epss, nvd. Public exploit references, when present, are outbound links only and are not proof of active exploitation. This is a catalog interpretation of stored metadata.

Exploitation and remediation

  • Exploitation evidence

    Confirmed in CISA KEV since Nov 3, 2021. Listed in the CISA Known Exploited Vulnerabilities catalog.

  • Patch and remediation

    Apply updates per vendor instructions. CISA due date May 3, 2022.

  • Safe detection guidance

    Compare installed versions with the affected ranges below and verify the advisory from the original publisher. This site stores metadata and outbound links only; it does not ship exploit code or proof-of-concept payloads.

Code

The project this record applies to. Exploit listings stay in References.

Timeline

Detection, updates, and resolution for this record.

  1. Oct 30, 2018 · Catalog

    Detected

    An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the "formsetUsbUnload" function executes

  2. Nov 3, 2021 · CISA KEV

    Known exploited

    Apply updates per vendor instructions.

  3. May 3, 2022 · CISA KEV

    Remediation due

    Apply updates per vendor instructions.

  4. Jun 16, 2026 · Catalog

    Updated

    An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the "formsetUsbUnload" function executes

Affected

  • cpe tenda/ac10 firmwareversion unspecified
  • cpe tenda/ac7 firmwareversion unspecified
  • cpe tenda/ac9 firmwareversion unspecified
  • vendor Tenda AC7, AC9, and AC10 Routersversion unspecified

Sources

  • CISA KEVConfirmed exploitationCVE-2018-14558

    Tenda AC7, AC9, and AC10 devices contain a command injection vulnerability due to the "formsetUsbUnload" function executes a dosystemCmd function with untrusted input. Successful exploitation allows an attacker to execute OS commands via a crafted goform/setUsbUnload request.

    cisa.gov
  • CVE.orgVulnerability recordCVE-2018-14558

    Official CVE identifier

    cve.org
  • FIRST EPSSExploitation probabilityCVE-2018-14558

    30-day exploitation probability 8.5%

    first.org
  • NIST NVDVulnerability recordCVE-2018-14558

    An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbit

    nvd.nist.gov

References