Vulnerability · CVE-2019-10891
D-Link dir-806_firmware Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Published Feb 1, 2023 · corrected/updated Feb 1, 2023 · D-Link dir-806_firmware · evidence confidence very high
An issue was discovered in D-Link DIR-806 devices. There is a command injection in function hnap_main, which calls system() without checking the parameter that can be controlled by user, and finally allows remote attackers to execute arbitrary shell commands with a special HTTP header. VulnCheck canary evidence.
Grounded briefings
Catalog interpretations for three audiences. Each brief cites ingested metadata and the original advisories below. They are not independent research and they do not invent exploit steps.
Executive
CVE-2019-10891 is a unknown public vulnerability record for D-Link dir-806_firmware. CISA lists it as known exploited. Published remediation guidance: Apply remediations or mitigations per vendor instructions or discontinue use of the product if remediation or mitigations are unavailable. This summary is a catalog interpretation of the ingested metadata and cites the original advisories below.
System administrator
Identify whether D-Link dir-806_firmware is in your estate, then compare installed versions with the affected ranges. Affected packages or ranges on record: D-Link dir-806_firmware. Published remediation guidance: Apply remediations or mitigations per vendor instructions or discontinue use of the product if remediation or mitigations are unavailable. Prefer the vendor or distribution advisory linked in Sources before changing production systems. This is a catalog interpretation, not a runbook.
Security analyst
Signals on file: no CVSS/EPSS yet. CISA lists it as known exploited. Sources contributing to this record: cve_org, vulncheck_kev. Public exploit references, when present, are outbound links only and are not proof of active exploitation. This is a catalog interpretation of stored metadata.
Exploitation and remediation
Exploitation evidence
Confirmed in CISA KEV since Feb 1, 2023. Listed in CISA KEV and VulnCheck KEV.
Patch and remediation
Apply remediations or mitigations per vendor instructions or discontinue use of the product if remediation or mitigations are unavailable.
Safe detection guidance
Compare installed versions with the affected ranges below and verify the advisory from the original publisher. This site stores metadata and outbound links only; it does not ship exploit code or proof-of-concept payloads.
Code
The project this record applies to. Exploit listings stay in References.
No public source repository is identified for this product.
Timeline
Detection, updates, and resolution for this record.
Feb 1, 2023 · VulnCheck KEV
Detected
An issue was discovered in D-Link DIR-806 devices. There is a command injection in function hnap_main, which calls system() without checking the parameter that can be controlled by user, and finally allows remote attackers to execute arbitrary shell commands with a special HTTP header. VulnCheck canary evidence.
Feb 1, 2023 · CISA KEV
Known exploited
Apply remediations or mitigations per vendor instructions or discontinue use of the product if remediation or mitigations are unavailable.
Affected
- vendor D-Link dir-806_firmwareversion unspecified
Sources
- CVE.orgVulnerability recordCVE-2019-10891
Official CVE identifier
cve.org - VulnCheck KEVConfirmed exploitationCVE-2019-10891
An issue was discovered in D-Link DIR-806 devices. There is a command injection in function hnap_main, which calls system() without checking the parameter that can be controlled by user, and finally allows remote attackers to execute arbitrary shell commands with a special HTTP h
vulncheck.com