Vulnerability · CVE-2019-25719
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling…
Published Jun 2, 2026 · corrected/updated Jul 22, 2026 · evidence confidence medium
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attackers with access to an enabled Infinity network port or physical proximity to a wireless access point can modify device settings such as alarm states or alarm limits, and overwhelm the system with incoming data causing the device to reboot and lose network functionality.
Grounded briefings
Catalog interpretations for three audiences. Each brief cites ingested metadata and the original advisories below. They are not independent research and they do not invent exploit steps.
Executive
CVE-2019-25719 is a high public vulnerability record for this product. It is not currently listed in the CISA Known Exploited catalog. Check the linked vendor or CERT advisories for patch status. This summary is a catalog interpretation of the ingested metadata and cites the original advisories below.
System administrator
Identify whether this product is in your estate, then compare installed versions with the affected ranges. Affected version ranges have not been ingested yet. Check the linked vendor or CERT advisories for patch status. Prefer the vendor or distribution advisory linked in Sources before changing production systems. This is a catalog interpretation, not a runbook.
Security analyst
Signals on file: CVSS 8.8. It is not currently listed in the CISA Known Exploited catalog. Weakness classes: CWE-924. Sources contributing to this record: nvd. Public exploit references, when present, are outbound links only and are not proof of active exploitation. This is a catalog interpretation of stored metadata.
Exploitation and remediation
Exploitation evidence
Not listed as known exploited in CISA KEV. Not in CISA KEV or VulnCheck KEV.
Patch and remediation
No required-action text is stored yet. Use the vendor or CERT links in Sources for patch availability.
Safe detection guidance
Compare installed versions with the affected ranges below and verify the advisory from the original publisher. This site stores metadata and outbound links only; it does not ship exploit code or proof-of-concept payloads.
Code
The project this record applies to. Exploit listings stay in References.
No public source repository is identified for this product.
Timeline
Detection, updates, and resolution for this record.
Jun 2, 2026 · NIST NVD
Detected
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attackers with access to an enabled Infinity network port or physical proximity to a wireless access point can
Jul 22, 2026 · NIST NVD
Updated
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attackers with access to an enabled Infinity network port or physical proximity to a wireless access point can
Sources
- NIST NVDVulnerability recordCVE-2019-25719
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service co
nvd.nist.gov