Vulnerability · CVE-2022-37129
D-Link dir-816_firmware Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Published Oct 9, 2025 · corrected/updated Oct 9, 2025 · D-Link dir-816_firmware · evidence confidence very high
D-Link DIR-816 A2_v1.10CNB04.img is vulnerable to Command Injection via /goform/SystemCommand. After the user passes in the command parameter, it will be spliced into byte_4836B0 by snprintf, and finally doSystem(&byte_4836B0); will be executed, resulting in a command injection.
Grounded briefings
Catalog interpretations for three audiences. Each brief cites ingested metadata and the original advisories below. They are not independent research and they do not invent exploit steps.
Executive
CVE-2022-37129 is a unknown public vulnerability record for D-Link dir-816_firmware. CISA lists it as known exploited. Published remediation guidance: Apply remediations or mitigations per vendor instructions or discontinue use of the product if remediation or mitigations are unavailable. This summary is a catalog interpretation of the ingested metadata and cites the original advisories below.
System administrator
Identify whether D-Link dir-816_firmware is in your estate, then compare installed versions with the affected ranges. Affected packages or ranges on record: D-Link dir-816_firmware. Published remediation guidance: Apply remediations or mitigations per vendor instructions or discontinue use of the product if remediation or mitigations are unavailable. Prefer the vendor or distribution advisory linked in Sources before changing production systems. This is a catalog interpretation, not a runbook.
Security analyst
Signals on file: no CVSS/EPSS yet. CISA lists it as known exploited. Sources contributing to this record: vulncheck_kev. Public exploit references, when present, are outbound links only and are not proof of active exploitation. This is a catalog interpretation of stored metadata.
Exploitation and remediation
Exploitation evidence
Confirmed in CISA KEV since Oct 9, 2025. Listed in CISA KEV and VulnCheck KEV.
Patch and remediation
Apply remediations or mitigations per vendor instructions or discontinue use of the product if remediation or mitigations are unavailable.
Safe detection guidance
Compare installed versions with the affected ranges below and verify the advisory from the original publisher. This site stores metadata and outbound links only; it does not ship exploit code or proof-of-concept payloads.
Code
The project this record applies to. Exploit listings stay in References.
No public source repository is identified for this product.
Timeline
Detection, updates, and resolution for this record.
Oct 9, 2025 · VulnCheck KEV
Detected
D-Link DIR-816 A2_v1.10CNB04.img is vulnerable to Command Injection via /goform/SystemCommand. After the user passes in the command parameter, it will be spliced into byte_4836B0 by snprintf, and finally doSystem(&byte_4836B0); will be executed, resulting in a command injection.
Oct 9, 2025 · CISA KEV
Known exploited
Apply remediations or mitigations per vendor instructions or discontinue use of the product if remediation or mitigations are unavailable.
Affected
- vendor D-Link dir-816_firmwareversion unspecified
Sources
- VulnCheck KEVConfirmed exploitationCVE-2022-37129
D-Link DIR-816 A2_v1.10CNB04.img is vulnerable to Command Injection via /goform/SystemCommand. After the user passes in the command parameter, it will be spliced into byte_4836B0 by snprintf, and finally doSystem(&byte_4836B0); will be executed, resulting in a command injection.
vulncheck.com