Findings

Vulnerability · CVE-2025-24909

Overview The software does not neutralize or incorrectly neutralize user-controllable input before it is placed in output that is used as a web page that is served to other users.

Published Apr 16, 2025 · corrected/updated Apr 17, 2025 · Hitachi Vantara Pentaho Business Analytics Server · evidence confidence high

Overview The software does not neutralize or incorrectly neutralize user-controllable input before it is placed in output that is used as a web page that is served to other users. (CWE-79) Description Hitachi Vantara Pentaho Business Analytics Server prior to versions 10.2.0.2, including 9.3.x and 8.3.x, allow a malicious URL to inject content into the Analyzer plugin interface. Impact Once the malicious script is injected, the attacker can perform a variety of malicious activities. The attacker could transfer private information, such as cookies that may include session information, from the

Grounded briefings

Catalog interpretations for three audiences. Each brief cites ingested metadata and the original advisories below. They are not independent research and they do not invent exploit steps.

Executive

CVE-2025-24909 is a medium public vulnerability record for Hitachi Vantara Pentaho Business Analytics Server. It is not currently listed in the CISA Known Exploited catalog. Check the linked vendor or CERT advisories for patch status. This summary is a catalog interpretation of the ingested metadata and cites the original advisories below.

System administrator

Identify whether Hitachi Vantara Pentaho Business Analytics Server is in your estate, then compare installed versions with the affected ranges. Affected packages or ranges on record: Hitachi Vantara Pentaho Business Analytics Server 10.0 <10.2.0.2 (10.0 <10.2.0.2). Check the linked vendor or CERT advisories for patch status. Prefer the vendor or distribution advisory linked in Sources before changing production systems. This is a catalog interpretation, not a runbook.

Security analyst

Signals on file: CVSS 4.4, EPSS 30.0%. It is not currently listed in the CISA Known Exploited catalog. Sources contributing to this record: euvd. Public exploit references, when present, are outbound links only and are not proof of active exploitation. This is a catalog interpretation of stored metadata.

Exploitation and remediation

  • Exploitation evidence

    Not listed as known exploited in CISA KEV. Not in CISA KEV or VulnCheck KEV.

  • Patch and remediation

    No required-action text is stored yet. Use the vendor or CERT links in Sources for patch availability.

  • Safe detection guidance

    Compare installed versions with the affected ranges below and verify the advisory from the original publisher. This site stores metadata and outbound links only; it does not ship exploit code or proof-of-concept payloads.

Code

The project this record applies to. Exploit listings stay in References.

No public source repository is identified for this product.

Timeline

Detection, updates, and resolution for this record.

  1. Apr 16, 2025 · EUVD

    Detected

    Overview The software does not neutralize or incorrectly neutralize user-controllable input before it is placed in output that is used as a web page that is served to other users. (CWE-79) Description Hitachi Vantara Pentaho Business Analytics Server prior to versions 10.2.0.2, including 9.3.x and 8.3.x, allow a malicious URL to inject content into the Analyzer plugin interface. Impact Once the ma

  2. Apr 17, 2025 · EUVD

    Updated

    Overview The software does not neutralize or incorrectly neutralize user-controllable input before it is placed in output that is used as a web page that is served to other users. (CWE-79) Description Hitachi Vantara Pentaho Business Analytics Server prior to versions 10.2.0.2, including 9.3.x and 8.3.x, allow a malicious URL to inject content into the Analyzer plugin interface. Impact Once the ma

Affected

  • vendor Hitachi Vantara Pentaho Business Analytics Server 10.0 <10.2.0.210.0 <10.2.0.2

Sources

  • EUVDVulnerability recordEUVD-2025-11526

    Overview The software does not neutralize or incorrectly neutralize user-controllable input before it is placed in output that is used as a web page that is served to other users. (CWE-79) Description Hitachi Vantara Pentaho Business Analytics Server prior to versions 10.2.0.2, i

    euvd.enisa.europa.eu

References