Findings

Vulnerability · CVE-2025-30002

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2).

Published Apr 16, 2025 · corrected/updated Apr 16, 2025 · Siemens TeleControl Server Basic · evidence confidence high

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25909)

Grounded briefings

Catalog interpretations for three audiences. Each brief cites ingested metadata and the original advisories below. They are not independent research and they do not invent exploit steps.

Executive

CVE-2025-30002 is a high public vulnerability record for Siemens TeleControl Server Basic. It is not currently listed in the CISA Known Exploited catalog. Check the linked vendor or CERT advisories for patch status. This summary is a catalog interpretation of the ingested metadata and cites the original advisories below.

System administrator

Identify whether Siemens TeleControl Server Basic is in your estate, then compare installed versions with the affected ranges. Affected packages or ranges on record: Siemens TeleControl Server Basic 0 <V3.1.2.2 (0 <V3.1.2.2). Check the linked vendor or CERT advisories for patch status. Prefer the vendor or distribution advisory linked in Sources before changing production systems. This is a catalog interpretation, not a runbook.

Security analyst

Signals on file: CVSS 8.7, EPSS 88.0%. It is not currently listed in the CISA Known Exploited catalog. Sources contributing to this record: euvd. Public exploit references, when present, are outbound links only and are not proof of active exploitation. This is a catalog interpretation of stored metadata.

Exploitation and remediation

  • Exploitation evidence

    Not listed as known exploited in CISA KEV. Not in CISA KEV or VulnCheck KEV.

  • Patch and remediation

    No required-action text is stored yet. Use the vendor or CERT links in Sources for patch availability.

  • Safe detection guidance

    Compare installed versions with the affected ranges below and verify the advisory from the original publisher. This site stores metadata and outbound links only; it does not ship exploit code or proof-of-concept payloads.

Code

The project this record applies to. Exploit listings stay in References.

No public source repository is identified for this product.

Timeline

Detection, updates, and resolution for this record.

  1. Apr 16, 2025 · EUVD

    Detected

    A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService"

  2. Apr 16, 2025 · EUVD

    Updated

    A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService"

Affected

  • vendor Siemens TeleControl Server Basic 0 <V3.1.2.20 <V3.1.2.2

Sources

  • EUVDVulnerability recordEUVD-2025-11385

    A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateConnectionVariables' method. This could allow an authenticated remote attacker to bypass authoriza

    euvd.enisa.europa.eu

References