Findings

Vulnerability · CVE-2025-32002

Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in I-O DATA network attached hard disk 'HDL-T Series' firmware Ver.1.21 and

Published May 15, 2025 · corrected/updated May 15, 2025 · I-O DATA DEVICE, INC. HDL-TC500 · evidence confidence high

Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in I-O DATA network attached hard disk 'HDL-T Series' firmware Ver.1.21 and earlier when 'Remote Link3 function' is enabled. If exploited, a remote unauthenticated attacker may execute an arbitrary OS command.

Grounded briefings

Catalog interpretations for three audiences. Each brief cites ingested metadata and the original advisories below. They are not independent research and they do not invent exploit steps.

Executive

CVE-2025-32002 is a critical public vulnerability record for I-O DATA DEVICE, INC. HDL-TC500. It is not currently listed in the CISA Known Exploited catalog. Check the linked vendor or CERT advisories for patch status. This summary is a catalog interpretation of the ingested metadata and cites the original advisories below.

System administrator

Identify whether I-O DATA DEVICE, INC. HDL-TC500 is in your estate, then compare installed versions with the affected ranges. Affected packages or ranges on record: I-O DATA DEVICE, INC. HDL-TC500 Ver.1.21 and earlier (Ver.1.21 and earlier). Check the linked vendor or CERT advisories for patch status. Prefer the vendor or distribution advisory linked in Sources before changing production systems. This is a catalog interpretation, not a runbook.

Security analyst

Signals on file: CVSS 9.3, EPSS 158.0%. It is not currently listed in the CISA Known Exploited catalog. Sources contributing to this record: euvd. Public exploit references, when present, are outbound links only and are not proof of active exploitation. This is a catalog interpretation of stored metadata.

Exploitation and remediation

  • Exploitation evidence

    Not listed as known exploited in CISA KEV. Not in CISA KEV or VulnCheck KEV.

  • Patch and remediation

    No required-action text is stored yet. Use the vendor or CERT links in Sources for patch availability.

  • Safe detection guidance

    Compare installed versions with the affected ranges below and verify the advisory from the original publisher. This site stores metadata and outbound links only; it does not ship exploit code or proof-of-concept payloads.

Code

The project this record applies to. Exploit listings stay in References.

No public source repository is identified for this product.

Timeline

Detection, updates, and resolution for this record.

  1. May 15, 2025 · EUVD

    Detected

    Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in I-O DATA network attached hard disk 'HDL-T Series' firmware Ver.1.21 and earlier when 'Remote Link3 function' is enabled. If exploited, a remote unauthenticated attacker may execute an arbitrary OS command.

  2. May 15, 2025 · EUVD

    Updated

    Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in I-O DATA network attached hard disk 'HDL-T Series' firmware Ver.1.21 and earlier when 'Remote Link3 function' is enabled. If exploited, a remote unauthenticated attacker may execute an arbitrary OS command.

Affected

  • vendor I-O DATA DEVICE, INC. HDL-TC500 Ver.1.21 and earlierVer.1.21 and earlier

Sources

  • EUVDVulnerability recordEUVD-2025-15148

    Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in I-O DATA network attached hard disk 'HDL-T Series' firmware Ver.1.21 and earlier when 'Remote Link3 function' is enabled. If exploited, a remote unauthenticated attacker may

    euvd.enisa.europa.eu