CVE-2026-4961
A vulnerability was identified in Tenda AC6 15.03.05.16.
Published Mar 27, 2026 · corrected/updated Jun 17, 2026 · tenda ac6 firmware · evidence confidence medium
A vulnerability was identified in Tenda AC6 15.03.05.16. Affected by this vulnerability is the function formQuickIndex of the file /goform/QuickIndex of the component POST Request Handler. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is publicly available and might be used.
Grounded briefings
Catalog interpretations for three audiences. Each brief cites ingested metadata and the original advisories below. They are not independent research and they do not invent exploit steps.
Executive
CVE-2026-4961 is a high public vulnerability record for tenda ac6 firmware. It is not currently listed in the CISA Known Exploited catalog. Check the linked vendor or CERT advisories for patch status. This summary is a catalog interpretation of the ingested metadata and cites the original advisories below.
System administrator
Identify whether tenda ac6 firmware is in your estate, then compare installed versions with the affected ranges. Affected packages or ranges on record: tenda/ac6 firmware (15.03.05.16). Check the linked vendor or CERT advisories for patch status. Prefer the vendor or distribution advisory linked in Sources before changing production systems. This is a catalog interpretation, not a runbook.
Security analyst
Signals on file: CVSS 7.4. It is not currently listed in the CISA Known Exploited catalog. Weakness classes: CWE-119, CWE-121, CWE-787. Sources contributing to this record: cve_org, nvd. Public exploit references, when present, are outbound links only and are not proof of active exploitation. This is a catalog interpretation of stored metadata.
Exploitation and remediation
Exploitation evidence
Not listed as known exploited in CISA KEV. Not in the CISA KEV catalog.
Patch and remediation
No required-action text is stored yet. Use the vendor or CERT links in Sources for patch availability.
Safe detection guidance
Compare installed versions with the affected ranges below and verify the advisory from the original publisher. This site stores metadata and outbound links only; it does not ship exploit code or proof-of-concept payloads.
Code
The project this record applies to. Exploit listings stay in References.
No public source repository is identified for this product.
Timeline
Detection, updates, and resolution for this record.
Mar 27, 2026 · NIST NVD
Detected
A vulnerability was identified in Tenda AC6 15.03.05.16. Affected by this vulnerability is the function formQuickIndex of the file /goform/QuickIndex of the component POST Request Handler. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is publicly available and might be used.
Jun 17, 2026 · NIST NVD
Updated
A vulnerability was identified in Tenda AC6 15.03.05.16. Affected by this vulnerability is the function formQuickIndex of the file /goform/QuickIndex of the component POST Request Handler. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is publicly available and might be used.
Affected
- cpe tenda/ac6 firmware15.03.05.16
Sources
- CVE.orgVulnerability recordCVE-2026-4961
Official CVE identifier
cve.org - NIST NVDVulnerability recordCVE-2026-4961
A vulnerability was identified in Tenda AC6 15.03.05.16. Affected by this vulnerability is the function formQuickIndex of the file /goform/QuickIndex of the component POST Request Handler. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The at
nvd.nist.gov