Findings

CVE-2026-5944

An improper access control vulnerability exists in the Cisco Intersight Device Connector for Nutanix Prism Central.

Published Apr 28, 2026 · updated Jun 17, 2026 · cisco intersight device connector

An improper access control vulnerability exists in the Cisco Intersight Device Connector for Nutanix Prism Central. The service exposes an API passthrough endpoint on TCP port 7373 that is accessible within the network scope of the deployment environment without authentication. An unauthenticated attacker with network access can exploit this vulnerability by sending crafted requests to the exposed endpoint to enumerate cluster metadata, including virtual machine information and cluster configuration details. While the API primarily supports read-only operations, it also allows certain cluster maintenance workflows to be invoked. Although this vulnerability does not allow persistent modification of system configurations or access to credentials or sensitive user data, successful exploitation may result in disruption of active workloads, leading to loss of service availability within the affected environment.

Code

The project this record applies to. Exploit listings stay in References.

No public source repository is identified for this product.

Timeline

Detection, updates, and resolution for this record.

  1. Apr 28, 2026 · NIST NVD

    Detected

    An improper access control vulnerability exists in the Cisco Intersight Device Connector for Nutanix Prism Central. The service exposes an API passthrough endpoint on TCP port 7373 that is accessible within the network scope of the deployment environment without authentication. An unauthenticated attacker with network access can exploit this vulnerability by sending crafted requests to the exposed

  2. Jun 17, 2026 · NIST NVD

    Updated

    An improper access control vulnerability exists in the Cisco Intersight Device Connector for Nutanix Prism Central. The service exposes an API passthrough endpoint on TCP port 7373 that is accessible within the network scope of the deployment environment without authentication. An unauthenticated attacker with network access can exploit this vulnerability by sending crafted requests to the exposed

Affected

  • cpe cisco/intersight device connectorversion unspecified

Sources

  • CVE.orgVulnerability recordCVE-2026-5944

    Official CVE identifier

    cve.org
  • NIST NVDVulnerability recordCVE-2026-5944

    An improper access control vulnerability exists in the Cisco Intersight Device Connector for Nutanix Prism Central. The service exposes an API passthrough endpoint on TCP port 7373 that is accessible within the network scope of the deployment environment without authentication.

    nvd.nist.gov

References