Findings

CVE-2026-7099

A vulnerability was detected in Tenda F456 1.0.0.5.

Published Apr 27, 2026 · corrected/updated Jun 17, 2026 · tenda f456 firmware · evidence confidence medium

A vulnerability was detected in Tenda F456 1.0.0.5. The affected element is the function formQuickIndex of the file /goform/QuickIndex of the component httpd. Performing a manipulation of the argument mit_linktype results in buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used.

Grounded briefings

Catalog interpretations for three audiences. Each brief cites ingested metadata and the original advisories below. They are not independent research and they do not invent exploit steps.

Executive

CVE-2026-7099 is a high public vulnerability record for tenda f456 firmware. It is not currently listed in the CISA Known Exploited catalog. Check the linked vendor or CERT advisories for patch status. This summary is a catalog interpretation of the ingested metadata and cites the original advisories below.

System administrator

Identify whether tenda f456 firmware is in your estate, then compare installed versions with the affected ranges. Affected packages or ranges on record: tenda/f456 firmware (1.0.0.5). Check the linked vendor or CERT advisories for patch status. Prefer the vendor or distribution advisory linked in Sources before changing production systems. This is a catalog interpretation, not a runbook.

Security analyst

Signals on file: CVSS 7.4. It is not currently listed in the CISA Known Exploited catalog. Weakness classes: CWE-119, CWE-120. Sources contributing to this record: cve_org, nvd. Public exploit references, when present, are outbound links only and are not proof of active exploitation. This is a catalog interpretation of stored metadata.

Exploitation and remediation

  • Exploitation evidence

    Not listed as known exploited in CISA KEV. Not in the CISA KEV catalog.

  • Patch and remediation

    No required-action text is stored yet. Use the vendor or CERT links in Sources for patch availability.

  • Safe detection guidance

    Compare installed versions with the affected ranges below and verify the advisory from the original publisher. This site stores metadata and outbound links only; it does not ship exploit code or proof-of-concept payloads.

Code

The project this record applies to. Exploit listings stay in References.

No public source repository is identified for this product.

Timeline

Detection, updates, and resolution for this record.

  1. Apr 27, 2026 · NIST NVD

    Detected

    A vulnerability was detected in Tenda F456 1.0.0.5. The affected element is the function formQuickIndex of the file /goform/QuickIndex of the component httpd. Performing a manipulation of the argument mit_linktype results in buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used.

  2. Jun 17, 2026 · NIST NVD

    Updated

    A vulnerability was detected in Tenda F456 1.0.0.5. The affected element is the function formQuickIndex of the file /goform/QuickIndex of the component httpd. Performing a manipulation of the argument mit_linktype results in buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used.

Affected

  • cpe tenda/f456 firmware1.0.0.5

Sources

  • CVE.orgVulnerability recordCVE-2026-7099

    Official CVE identifier

    cve.org
  • NIST NVDVulnerability recordCVE-2026-7099

    A vulnerability was detected in Tenda F456 1.0.0.5. The affected element is the function formQuickIndex of the file /goform/QuickIndex of the component httpd. Performing a manipulation of the argument mit_linktype results in buffer overflow. The attack may be initiated remotely.

    nvd.nist.gov

References