A vulnerability has been identified in Building X - Security Manager Edge Controller (ACC-AP) (All versions).

Published May 23, 2025 · catalog updated Dec 9, 2025 · Siemens Building X - Security Manager Edge Controller (ACC-AP)

Check this week

CVE-2022-31807 is not in CISA KEV. FIRST estimates a 16.00% chance of exploitation in the next 30 days. Check whether you run Siemens Building X - Security Manager Edge Controller (ACC-AP).

Gaps on this record

  • No vendor fix or required action is stored. Compare the linked advisory before you change production.
Severity
Medium5.9
Known exploitation
Not in CISA/VulnCheck KEV
EPSS
16.00%
Remediation
Version ranges on file
Affected products
vendor Siemens Building X - Security Manager Edge Controller (ACC-AP) 0 <*

A vulnerability has been identified in Building X - Security Manager Edge Controller (ACC-AP) (All versions). Affected devices do not properly check the integrity of firmware updates. This could allow a local attacker to upload a maliciously modified firmware onto the device. In a second scenario, a remote attacker who is able to intercept the transfer of a valid firmware from the server to the device could modify the firmware "on the fly".

Are you affected?

Enter the version you run. The result uses only the ranges stored on this record.

The check returns affected, not affected, or incomplete. It does not guess a version that is missing from the record.

  • vendor Siemens Building X - Security Manager Edge Controller (ACC-AP) 0 <*0 <*

How to fix CVE-2022-31807

What to do

Three questions, each answered from this record only. Confirm the vendor advisory before you patch.

Should you patch?

CVE-2022-31807 is not in CISA KEV. FIRST estimates a 16.00% chance of exploitation in the next 30 days. Check whether you run Siemens Building X - Security Manager Edge Controller (ACC-AP).

Which versions are affected?

Compare what you have installed with Siemens Building X - Security Manager Edge Controller (ACC-AP) 0 <* 0 <*. Compare the installed version with the linked vendor advisory before you change production.

What should an analyst verify?

No weakness class is stored. EPSS 16.00%. There is no CISA KEV listing. No Exploit-DB or Metasploit reference is linked. Use the source links for the original advisory.

Code

The project this record applies to. Exploit listings stay in References.

No public source repository is identified for this product.

Timeline

Detection, updates, and resolution for this record.

  1. May 23, 2025 · EUVD

    Detected

    A vulnerability has been identified in Building X - Security Manager Edge Controller (ACC-AP) (All versions). Affected devices do not properly check the integrity of firmware updates. This could allow a local attacker to upload a maliciously modified firmware onto the device. In a second scenario, a remote attacker who is able to intercept the transfer of a valid firmware from the server to the de

  2. Dec 9, 2025 · EUVD

    Updated

    A vulnerability has been identified in Building X - Security Manager Edge Controller (ACC-AP) (All versions). Affected devices do not properly check the integrity of firmware updates. This could allow a local attacker to upload a maliciously modified firmware onto the device. In a second scenario, a remote attacker who is able to intercept the transfer of a valid firmware from the server to the de

Sources

  • CVE.orgVulnerability recordCVE-2022-31807

    Official CVE identifier

    cve.org
  • EUVDVulnerability recordEUVD-2022-54259

    A vulnerability has been identified in Building X - Security Manager Edge Controller (ACC-AP) (All versions). Affected devices do not properly check the integrity of firmware updates. This could allow a local attacker to upload a maliciously modified firmware onto the device. In

    euvd.enisa.europa.eu

References

Freshness

Last verified in this catalog Oct 18, 2026. Significant claims (KEV, EPSS, CVSS, affected ranges) come from the source rows above — open the original publisher for the authoritative advisory.