Vulnerabilities

Vulnerability · CVE-2024-41986

A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 = V13.2 = V13.2 < V2506).

Published Aug 12, 2025 · catalog updated Aug 12, 2025 · Siemens SOA Audit

Check if you run it

No confirmed exploitation is on record for CVE-2024-41986. EPSS is 0.12%. Act only if a listed version of Siemens SOA Audit is installed.

Gaps on this record

  • No vendor fix or required action is stored. Compare the linked advisory before you change production.
Severity
Medium6.1
Known exploitation
Not in CISA/VulnCheck KEV
EPSS
0.12%
Remediation
Version ranges on file
Affected products
vendor Siemens SOA Audit V13.2 <V2506

A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 = V13.2 = V13.2 < V2506). The affected application support insecure TLS 1.0 and 1.1 protocol. An attacker could achieve a man-in-the-middle attack and compromise confidentiality and integrity of data.

Are you affected?

Enter the version you run. The result uses only the ranges stored on this record.

The check returns affected, not affected, or incomplete. It does not guess a version that is missing from the record.

  • vendor Siemens SOA Audit V13.2 <V2506V13.2 <V2506

How to fix CVE-2024-41986

What to do

Three questions, each answered from this record only. Confirm the vendor advisory before you patch.

Should you patch?

No confirmed exploitation is on record for CVE-2024-41986. EPSS is 0.12%. Act only if a listed version of Siemens SOA Audit is installed.

Which versions are affected?

Compare what you have installed with Siemens SOA Audit V13.2 <V2506 V13.2 <V2506. Compare the installed version with the linked vendor advisory before you change production.

What should an analyst verify?

No weakness class is stored. EPSS 0.12%. There is no CISA KEV listing. No Exploit-DB or Metasploit reference is linked. Use the source links for the original advisory.

Code

The project this record applies to. Exploit listings stay in References.

No public source repository is identified for this product.

Timeline

Detection, updates, and resolution for this record.

  1. Aug 12, 2025 · EUVD

    Detected

    A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 = V13.2 = V13.2 < V2506). The affected application support insecure TLS 1.0 and 1.1 protocol. An attacker could achieve a man-in-the-middle attack and compromise confidentiality and integrity of data.

  2. Aug 12, 2025 · EUVD

    Updated

    A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 = V13.2 = V13.2 < V2506). The affected application support insecure TLS 1.0 and 1.1 protocol. An attacker could achieve a man-in-the-middle attack and compromise confidentiality and integrity of data.

Sources

  • CVE.orgVulnerability recordCVE-2024-41986

    Official CVE identifier

    cve.org
  • FIRST EPSSExploitation probabilityCVE-2024-41986

    30-day exploitation probability 0.12%

    first.org
  • EUVDVulnerability recordEUVD-2024-54864

    A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 = V13.2 = V13.2 < V2506). The affected application support insecure TLS 1.0 and 1.1 protocol. An attacker could achieve a man-in-the-middle attack and compromise confidentialit

    euvd.enisa.europa.eu

References

Freshness

Last verified in this catalog Oct 21, 2026. Significant claims (KEV, EPSS, CVSS, affected ranges) come from the source rows above — open the original publisher for the authoritative advisory.