Security incident · CVE-2025-3905
CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists impacting PLC system variables that could cause an unvalidated dat
Published Jun 10, 2025 · catalog updated Jun 10, 2025 · Schneider Electric Modicon Controllers M241/M251
Check if you run it
No confirmed exploitation is on record for CVE-2025-3905. EPSS is 0.30%. Act only if a listed version of Schneider Electric Modicon Controllers M241/M251 is installed.
Gaps on this record
- No vendor fix or required action is stored. Compare the linked advisory before you change production.
- Severity
- Medium5.1
- Known exploitation
- Not in CISA/VulnCheck KEV
- EPSS
- 0.30%
- Remediation
- Advisory link
- Affected products
- vendor Schneider Electric Modicon Controllers M241/M251 Versions prior to 5.3.12.51
CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists impacting PLC system variables that could cause an unvalidated data injected by authenticated malicious user leading to modify or read data in a victim’s browser.
Are you affected?
Enter the version you run. The result uses only the ranges stored on this record.
The check returns affected, not affected, or incomplete. It does not guess a version that is missing from the record.
- vendor Schneider Electric Modicon Controllers M241/M251 Versions prior to 5.3.12.51Versions prior to 5.3.12.51
How to fix CVE-2025-3905
Recommended remediation
A patch or advisory reference is linked. Open the original publisher for availability by product version.
Official advisories
What to do
Three questions, each answered from this record only. Confirm the vendor advisory before you patch.
Should you patch?
No confirmed exploitation is on record for CVE-2025-3905. EPSS is 0.30%. Act only if a listed version of Schneider Electric Modicon Controllers M241/M251 is installed.
Which versions are affected?
Compare what you have installed with Schneider Electric Modicon Controllers M241/M251 Versions prior to 5.3.12.51 Versions prior to 5.3.12.51. Compare the installed version with the linked vendor advisory before you change production.
What should an analyst verify?
No weakness class is stored. EPSS 0.30%. There is no CISA KEV listing. No Exploit-DB or Metasploit reference is linked. Use the source links for the original advisory.
Code
The project this record applies to. Exploit listings stay in References.
No public source repository is identified for this product.
Timeline
Detection, updates, and resolution for this record.
Jun 10, 2025 · EUVD
Detected
CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists impacting PLC system variables that could cause an unvalidated data injected by authenticated malicious user leading to modify or read data in a victim’s browser.
Jun 10, 2025 · EUVD
Updated
CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists impacting PLC system variables that could cause an unvalidated data injected by authenticated malicious user leading to modify or read data in a victim’s browser.
Sources
- CVE.orgVulnerability recordCVE-2025-3905
Official CVE identifier
cve.org - FIRST EPSSExploitation probabilityCVE-2025-3905
30-day exploitation probability 0.3%
first.org - EUVDVulnerability recordEUVD-2025-17646
CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists impacting PLC system variables that could cause an unvalidated data injected by authenticated malicious user leading to modify or read data in a victim’s browser.
euvd.enisa.europa.eu
References
Freshness
Last verified in this catalog Oct 18, 2026. Significant claims (KEV, EPSS, CVSS, affected ranges) come from the source rows above — open the original publisher for the authoritative advisory.