Vulnerability · CVE-2025-40743
A vulnerability has been identified in SINUMERIK 828D PPU.4 (All versions < V4.95 SP5), SINUMERIK 828D PPU.5 (All versions < V5.25 SP1), SINUMERIK 840D sl (All versions < V4.95 SP5
Published Aug 12, 2025 · catalog updated Aug 13, 2025 · Siemens SINUMERIK ONE V6.15
Check this week
CVE-2025-40743 is not in CISA KEV. FIRST estimates a 24.00% chance of exploitation in the next 30 days. Check whether you run Siemens SINUMERIK ONE V6.15.
Gaps on this record
- No vendor fix or required action is stored. Compare the linked advisory before you change production.
- Severity
- High8.7
- Known exploitation
- Not in CISA/VulnCheck KEV
- EPSS
- 24.00%
- Remediation
- Version ranges on file
- Affected products
- vendor Siemens SINUMERIK ONE V6.15 0 <V6.15 SP5
A vulnerability has been identified in SINUMERIK 828D PPU.4 (All versions < V4.95 SP5), SINUMERIK 828D PPU.5 (All versions < V5.25 SP1), SINUMERIK 840D sl (All versions < V4.95 SP5), SINUMERIK MC (All versions < V1.25 SP1), SINUMERIK MC V1.15 (All versions < V1.15 SP5), SINUMERIK ONE (All versions < V6.25 SP1), SINUMERIK ONE V6.15 (All versions < V6.15 SP5). The affected application improperly validates authentication for its VNC access service, allowing access with insufficient password verification. This could allow an attacker to gain unauthorized remote access and potentially compromise sy
Are you affected?
Enter the version you run. The result uses only the ranges stored on this record.
The check returns affected, not affected, or incomplete. It does not guess a version that is missing from the record.
- vendor Siemens SINUMERIK ONE V6.15 0 <V6.15 SP50 <V6.15 SP5
How to fix CVE-2025-40743
Recommended remediation
Affected version ranges suggest a fixed boundary. Verify against the vendor advisory for your release.
Official advisories
What to do
Three questions, each answered from this record only. Confirm the vendor advisory before you patch.
Should you patch?
CVE-2025-40743 is not in CISA KEV. FIRST estimates a 24.00% chance of exploitation in the next 30 days. Check whether you run Siemens SINUMERIK ONE V6.15.
Which versions are affected?
Compare what you have installed with Siemens SINUMERIK ONE V6.15 0 <V6.15 SP5 0 <V6.15 SP5. Compare the installed version with the linked vendor advisory before you change production.
What should an analyst verify?
No weakness class is stored. EPSS 24.00%. There is no CISA KEV listing. No Exploit-DB or Metasploit reference is linked. Use the source links for the original advisory.
Code
The project this record applies to. Exploit listings stay in References.
No public source repository is identified for this product.
Timeline
Detection, updates, and resolution for this record.
Aug 12, 2025 · EUVD
Detected
A vulnerability has been identified in SINUMERIK 828D PPU.4 (All versions < V4.95 SP5), SINUMERIK 828D PPU.5 (All versions < V5.25 SP1), SINUMERIK 840D sl (All versions < V4.95 SP5), SINUMERIK MC (All versions < V1.25 SP1), SINUMERIK MC V1.15 (All versions < V1.15 SP5), SINUMERIK ONE (All versions < V6.25 SP1), SINUMERIK ONE V6.15 (All versions < V6.15 SP5). The affected application improperly val
Aug 13, 2025 · EUVD
Updated
A vulnerability has been identified in SINUMERIK 828D PPU.4 (All versions < V4.95 SP5), SINUMERIK 828D PPU.5 (All versions < V5.25 SP1), SINUMERIK 840D sl (All versions < V4.95 SP5), SINUMERIK MC (All versions < V1.25 SP1), SINUMERIK MC V1.15 (All versions < V1.15 SP5), SINUMERIK ONE (All versions < V6.25 SP1), SINUMERIK ONE V6.15 (All versions < V6.15 SP5). The affected application improperly val
Sources
- EUVDVulnerability recordEUVD-2025-24245
A vulnerability has been identified in SINUMERIK 828D PPU.4 (All versions < V4.95 SP5), SINUMERIK 828D PPU.5 (All versions < V5.25 SP1), SINUMERIK 840D sl (All versions < V4.95 SP5), SINUMERIK MC (All versions < V1.25 SP1), SINUMERIK MC V1.15 (All versions < V1.15 SP5), SINUMERIK
euvd.enisa.europa.eu
References
Freshness
Last verified in this catalog Aug 13, 2025. Significant claims (KEV, EPSS, CVSS, affected ranges) come from the source rows above — open the original publisher for the authoritative advisory.