Vulnerabilities

Vulnerability · CVE-2025-4397

Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format.

Published May 7, 2026 · catalog updated Oct 14, 2026 · Medtronic MyCareLink Patient Monitor

Check if you run it

No confirmed exploitation is on record for CVE-2025-4397. EPSS is 0.13%. Act only if a listed version of Medtronic MyCareLink Patient Monitor is installed.

Gaps on this record

  • The stored product name is a package slug. The name on this page is taken from the title (Medtronic MyCareLink Patient Monitor).
  • No version range is stored. A customer cannot check an installed version against this record.
  • No vendor fix or required action is stored. Compare the linked advisory before you change production.
Severity
Medium6.8
Known exploitation
Not in CISA/VulnCheck KEV
EPSS
0.13%
Remediation
Advisory link
Affected products
See sources for product scope

Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials to modify encrypted drive data.

No affected version ranges are stored yet. Use the vendor advisory before you decide this record does not apply.

How to fix CVE-2025-4397

What to do

Three questions, each answered from this record only. Confirm the vendor advisory before you patch.

Should you patch?

No confirmed exploitation is on record for CVE-2025-4397. EPSS is 0.13%. Act only if a listed version of Medtronic MyCareLink Patient Monitor is installed.

Which versions are affected?

Affected version ranges are not on this record. Compare the installed version with the linked vendor advisory before you change production.

What should an analyst verify?

CWE-313. EPSS 0.13%. There is no CISA KEV listing. No Exploit-DB or Metasploit reference is linked. Use the source links for the original advisory.

Code

The project this record applies to. Exploit listings stay in References.

No public source repository is identified for this product.

Timeline

Detection, updates, and resolution for this record.

  1. May 7, 2026 · NIST NVD

    Detected

    Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials to modify encrypted drive data.

  2. Oct 14, 2026 · NIST NVD

    Updated

    Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials to modify encrypted drive data.

Sources

  • CVE.orgVulnerability recordCVE-2025-4397

    Official CVE identifier

    cve.org
  • FIRST EPSSExploitation probabilityCVE-2025-4397

    30-day exploitation probability 0.1%

    first.org
  • NIST NVDVulnerability recordCVE-2025-4397

    Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials to modify encrypted drive data.

    nvd.nist.gov

References

Freshness

Last verified in this catalog Oct 18, 2026. Significant claims (KEV, EPSS, CVSS, affected ranges) come from the source rows above — open the original publisher for the authoritative advisory.