Vulnerability · CVE-2025-54304
An issue was discovered on Thermo Fisher Ion Torrent OneTouch 2 INS1005527 devices.
Published Dec 4, 2025 · catalog updated Dec 5, 2025 · An issue was discovered
Last checked Oct 28, 2026. A connected source was read within the last 7 days.
Check if you run it
No confirmed exploitation is on record for CVE-2025-54304. EPSS is 0.50%. Act only if a listed version of An issue was discovered is installed.
Gaps on this record
- The stored product name is a package slug. The name on this page is taken from the title (An issue was discovered).
- No version range is stored. A customer cannot check an installed version against this record.
- No vendor fix or required action is stored. Compare the linked advisory before you change production.
Same product and reporting
- CVE-2026-107079 · Unknown
- CVE-2026-95168 · High
- CVE-2025-60475 · Medium
- CVE-2025-60494 · Unknown
- CVE-2025-60496 · Unknown
- Severity
- Critical9.8
- Known exploitation
- Not in CISA/VulnCheck KEV
- EPSS
- 0.50%
- Remediation
- Vendor / distro source
- Affected products
- vendor n/a n/a n/a
An issue was discovered on Thermo Fisher Ion Torrent OneTouch 2 INS1005527 devices. When they are powered on, an X11 display server is started. The display server listens on all network interfaces and is accessible over port 6000. The X11 access control list, by default, allows connections from 127.0.0.1 and 192.168.2.15. If a device is powered on and later connected to a network with DHCP, the device may not be assigned the 192.168.2.15 IP address, leaving the display server accessible by other devices on the network. The exposed X11 display server can then be used to gain root privileges and
Are you affected?
Enter the version you run. The result uses only the ranges stored on this record.
The check returns affected, not affected, or incomplete. It does not guess a version that is missing from the record.
- vendor n/a n/a n/an/a
How to fix CVE-2025-54304
No stored fix
No vendor fix text is stored. Use the linked advisory before you change production.
Version check
No version range is stored, so an installed version cannot be checked on this page.
Advisory
Open the cve_org record and follow its fix.
Official advisories
What to do
Three questions, each answered from this record only. Confirm the vendor advisory before you patch.
Should you patch?
No confirmed exploitation is on record for CVE-2025-54304. EPSS is 0.50%. Act only if a listed version of An issue was discovered is installed.
Which versions are affected?
Compare what you have installed with n/a n/a n/a n/a. Compare the installed version with the linked vendor advisory before you change production.
What should an analyst verify?
No weakness class is stored. EPSS 0.50%. There is no CISA KEV listing. No Exploit-DB or Metasploit reference is linked. Use the source links for the original advisory.
Code
The project this record applies to. Exploit listings stay in References.
No public source repository is identified for this product.
Timeline
Detection, updates, and resolution for this record.
Dec 4, 2025 · EUVD
Detected
An issue was discovered on Thermo Fisher Ion Torrent OneTouch 2 INS1005527 devices. When they are powered on, an X11 display server is started. The display server listens on all network interfaces and is accessible over port 6000. The X11 access control list, by default, allows connections from 127.0.0.1 and 192.168.2.15. If a device is powered on and later connected to a network with DHCP, the de
Dec 5, 2025 · EUVD
Updated
An issue was discovered on Thermo Fisher Ion Torrent OneTouch 2 INS1005527 devices. When they are powered on, an X11 display server is started. The display server listens on all network interfaces and is accessible over port 6000. The X11 access control list, by default, allows connections from 127.0.0.1 and 192.168.2.15. If a device is powered on and later connected to a network with DHCP, the de
Sources
- CVE.orgVulnerability recordCVE-2025-54304
Official CVE identifier
cve.org - FIRST EPSSExploitation probabilityCVE-2025-54304
30-day exploitation probability 0.50%
first.org - EUVDVulnerability recordEUVD-2025-201179
An issue was discovered on Thermo Fisher Ion Torrent OneTouch 2 INS1005527 devices. When they are powered on, an X11 display server is started. The display server listens on all network interfaces and is accessible over port 6000. The X11 access control list, by default, allows c
euvd.enisa.europa.eu
References
Freshness
Last verified in this catalog Oct 28, 2026. Significant claims (KEV, EPSS, CVSS, affected ranges) come from the source rows above — open the original publisher for the authoritative advisory.
- FIRST EPSSOct 28, 2026
- CVE.orgOct 28, 2026
- EUVDOct 27, 2026