Vulnerability · CVE-2025-69690
Netgate pfSense CE 2.7.2 allows code execution by using the module installer with a backup file with a serialized PHP object containing the post_reboot_commands property.
Published May 8, 2026 · catalog updated Oct 15, 2026 · Netgate pfSense CE 2.7.2
Check if you run it
No confirmed exploitation is on record for CVE-2025-69690. EPSS is 0.81%. Act only if a listed version of Netgate pfSense CE 2.7.2 is installed.
Gaps on this record
- The stored product name is a package slug. The name on this page is taken from the title (Netgate pfSense CE 2.7.2).
- No vendor fix or required action is stored. Compare the linked advisory before you change production.
- Severity
- Critical9.1
- Known exploitation
- Not in CISA/VulnCheck KEV
- EPSS
- 0.81%
- Remediation
- Not established
- Affected products
- cpe pfsense/pfsense
Netgate pfSense CE 2.7.2 allows code execution by using the module installer with a backup file with a serialized PHP object containing the post_reboot_commands property. NOTE: the Supplier disputes this because this installer is only available to admins and they are intentionally allowed to execute PHP code.
Are you affected?
Enter the version you run. The result uses only the ranges stored on this record.
The check returns affected, not affected, or incomplete. It does not guess a version that is missing from the record.
- cpe pfsense/pfsense2.7.2
How to fix CVE-2025-69690
Recommended remediation
No required-action text, fix commit, or clear fixed-version range is stored yet.
Official advisories
What to do
Three questions, each answered from this record only. Confirm the vendor advisory before you patch.
Should you patch?
No confirmed exploitation is on record for CVE-2025-69690. EPSS is 0.81%. Act only if a listed version of Netgate pfSense CE 2.7.2 is installed.
Which versions are affected?
Compare what you have installed with 2.7.2. Compare the installed version with the linked vendor advisory before you change production.
What should an analyst verify?
CWE-502: Deserialization of Untrusted Data; CWE-915: Improperly Controlled Modification of Dynamically-Determined Object Attributes. EPSS 0.81%. There is no CISA KEV listing. No Exploit-DB or Metasploit reference is linked. Use the source links for the original advisory.
Code
The project this record applies to. Exploit listings stay in References.
No public source repository is identified for this product.
Timeline
Detection, updates, and resolution for this record.
May 8, 2026 · NIST NVD
Detected
Netgate pfSense CE 2.7.2 allows code execution by using the module installer with a backup file with a serialized PHP object containing the post_reboot_commands property. NOTE: the Supplier disputes this because this installer is only available to admins and they are intentionally allowed to execute PHP code.
Oct 15, 2026 · NIST NVD
Updated
Netgate pfSense CE 2.7.2 allows code execution by using the module installer with a backup file with a serialized PHP object containing the post_reboot_commands property. NOTE: the Supplier disputes this because this installer is only available to admins and they are intentionally allowed to execute PHP code.
Sources
- CVE.orgVulnerability recordCVE-2025-69690
Official CVE identifier
cve.org - FIRST EPSSExploitation probabilityCVE-2025-69690
30-day exploitation probability 0.8%
first.org - NIST NVDVulnerability recordCVE-2025-69690
Netgate pfSense CE 2.7.2 allows code execution by using the module installer with a backup file with a serialized PHP object containing the post_reboot_commands property. NOTE: the Supplier disputes this because this installer is only available to admins and they are intentionall
nvd.nist.gov
References
Freshness
Last verified in this catalog Oct 18, 2026. Significant claims (KEV, EPSS, CVSS, affected ranges) come from the source rows above — open the original publisher for the authoritative advisory.