Vulnerability · CVE-2025-9063

An authentication bypass security issue exists within FactoryTalk View Machine Edition Web Browser ActiveX control.

Published Oct 14, 2025 · catalog updated Oct 14, 2025 · Rockwell Automation PanelView Plus 7 Performance Series B

Last checked Nov 6, 2026. A connected source was read within the last 7 days.

Check if you run it

No confirmed exploitation is on record for CVE-2025-9063. EPSS is 0.40%. Act only if a listed version of Rockwell Automation PanelView Plus 7 Performance Series B is installed.

Gaps on this record

  • No vendor fix or required action is stored. Compare the linked advisory before you change production.
Severity
High7.0
Known exploitation
Not in CISA/VulnCheck KEV
EPSS
0.40%
Remediation
Advisory link
Affected products
vendor Rockwell Automation PanelView Plus 7 Performance Series B V14.00

An authentication bypass security issue exists within FactoryTalk View Machine Edition Web Browser ActiveX control. Exploitation of this vulnerability allows unauthorized access to the PanelView Plus 7 Series B, including access to the file system, retrieval of diagnostic information, event logs, and more.

Are you affected?

Enter the version you run. The result uses only the ranges stored on this record.

The check returns affected, not affected, or incomplete. It does not guess a version that is missing from the record.

  • vendor Rockwell Automation PanelView Plus 7 Performance Series B V14.00V14.00

How to fix CVE-2025-9063

What to do

Three questions, each answered from this record only. Confirm the vendor advisory before you patch.

Should you patch?

No confirmed exploitation is on record for CVE-2025-9063. EPSS is 0.40%. Act only if a listed version of Rockwell Automation PanelView Plus 7 Performance Series B is installed.

Which versions are affected?

Compare what you have installed with Rockwell Automation PanelView Plus 7 Performance Series B V14.00 V14.00. Compare the installed version with the linked vendor advisory before you change production.

What should an analyst verify?

No weakness class is stored. EPSS 0.40%. There is no CISA KEV listing. No Exploit-DB or Metasploit reference is linked. Use the source links for the original advisory.

Code

The project this record applies to. Exploit listings stay in References.

No public source repository is identified for this product.

Timeline

Detection, updates, and resolution for this record.

  1. Oct 14, 2025 · EUVD

    Detected

    An authentication bypass security issue exists within FactoryTalk View Machine Edition Web Browser ActiveX control. Exploitation of this vulnerability allows unauthorized access to the PanelView Plus 7 Series B, including access to the file system, retrieval of diagnostic information, event logs, and more.

  2. Oct 14, 2025 · EUVD

    Updated

    An authentication bypass security issue exists within FactoryTalk View Machine Edition Web Browser ActiveX control. Exploitation of this vulnerability allows unauthorized access to the PanelView Plus 7 Series B, including access to the file system, retrieval of diagnostic information, event logs, and more.

Sources

  • CVE.orgVulnerability recordCVE-2025-9063

    Official CVE identifier

    cve.org
  • FIRST EPSSExploitation probabilityCVE-2025-9063

    30-day exploitation probability 0.40%

    first.org
  • EUVDVulnerability recordEUVD-2025-34185

    An authentication bypass security issue exists within FactoryTalk View Machine Edition Web Browser ActiveX control. Exploitation of this vulnerability allows unauthorized access to the PanelView Plus 7 Series B, including access to the file system, retrieval of diagnostic informa

    euvd.enisa.europa.eu

References

Freshness

Last verified in this catalog Nov 6, 2026. Significant claims (KEV, EPSS, CVSS, affected ranges) come from the source rows above — open the original publisher for the authoritative advisory.

  • FIRST EPSSNov 6, 2026
  • CVE.orgOct 23, 2026
  • EUVDOct 23, 2026