Vulnerability · CVE-2025-9356
A vulnerability was determined in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001.
Published Aug 22, 2025 · catalog updated Aug 26, 2025 · Linksys RE7000
Last checked Oct 26, 2026. A connected source was read within the last 7 days.
Check if you run it
No confirmed exploitation is on record for CVE-2025-9356. EPSS is 1.01%. Act only if a listed version of Linksys RE7000 is installed.
Gaps on this record
- No vendor fix or required action is stored. Compare the linked advisory before you change production.
Same product and reporting
- CVE-2025-9359 · High
- CVE-2025-8832 · High
- CVE-2025-8831 · High
- CVE-2025-8830 · Medium
- CVE-2025-8828 · Medium
- Severity
- High8.7
- Known exploitation
- Not in CISA/VulnCheck KEV
- EPSS
- 1.01%
- Remediation
- Vendor / distro source
- Affected products
- vendor Linksys RE7000 1.0.013.001
A vulnerability was determined in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected by this issue is the function inboundFilterAdd of the file /goform/inboundFilterAdd. Executing manipulation of the argument ruleName can lead to stack-based buffer overflow. The attack may be performed from a remote location. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.
Are you affected?
Enter the version you run. The result uses only the ranges stored on this record.
The check returns affected, not affected, or incomplete. It does not guess a version that is missing from the record.
- vendor Linksys RE7000 1.0.013.0011.0.013.001
How to fix CVE-2025-9356
No stored fix
No vendor fix text is stored. Use the linked advisory before you change production.
Version check
Seen in 1.0.013.001
Advisory
Open the cve_org record and follow its fix.
Official advisories
What to do
Three questions, each answered from this record only. Confirm the vendor advisory before you patch.
Should you patch?
No confirmed exploitation is on record for CVE-2025-9356. EPSS is 1.01%. Act only if a listed version of Linksys RE7000 is installed.
Which versions are affected?
Compare what you have installed with Linksys RE7000 1.0.013.001 1.0.013.001. Compare the installed version with the linked vendor advisory before you change production.
What should an analyst verify?
No weakness class is stored. EPSS 1.01%. There is no CISA KEV listing. No Exploit-DB or Metasploit reference is linked. Use the source links for the original advisory.
Code
The project this record applies to. Exploit listings stay in References.
Timeline
Detection, updates, and resolution for this record.
Aug 22, 2025 · EUVD
Detected
A vulnerability was determined in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected by this issue is the function inboundFilterAdd of the file /goform/inboundFilterAdd. Executing manipulation of the argument ruleName can lead to stack-based buffer overflow. The attack may be performed from a remote location. The exploit has
Aug 26, 2025 · EUVD
Updated
A vulnerability was determined in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected by this issue is the function inboundFilterAdd of the file /goform/inboundFilterAdd. Executing manipulation of the argument ruleName can lead to stack-based buffer overflow. The attack may be performed from a remote location. The exploit has
Sources
- CVE.orgVulnerability recordCVE-2025-9356
Official CVE identifier
cve.org - FIRST EPSSExploitation probabilityCVE-2025-9356
30-day exploitation probability 1.01%
first.org - EUVDVulnerability recordEUVD-2025-28837
A vulnerability was determined in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected by this issue is the function inboundFilterAdd of the file /goform/inboundFilterAdd. Executing manipulation of the argumen
euvd.enisa.europa.eu
References
Freshness
Last verified in this catalog Oct 26, 2026. Significant claims (KEV, EPSS, CVSS, affected ranges) come from the source rows above — open the original publisher for the authoritative advisory.
- FIRST EPSSOct 23, 2026
- CVE.orgOct 22, 2026
- EUVDOct 22, 2026