Vulnerability · CVE-2026-109439

Lantronix XPress-DR and XPress-DR-I (CoBos-family) firmware through 8.1.0.0 contains a missing authentication vulnerability that allows remote attackers to read and pe…

Published Oct 14, 2026 · catalog updated Oct 14, 2026 · the affected product

Check if you run it

No confirmed exploitation is on record for CVE-2026-109439. EPSS is 0.62%. Act only if a listed version of the affected product is installed.

Gaps on this record

  • No plain product name is stored. The page cannot tell you which product to check.
  • No version range is stored. A customer cannot check an installed version against this record.
  • No vendor fix or required action is stored. Compare the linked advisory before you change production.
Severity
Critical9.3
Known exploitation
Not in CISA/VulnCheck KEV
EPSS
0.62%
Remediation
Not established
Affected products
See sources for product scope

Lantronix XPress-DR and XPress-DR-I (CoBos-family) firmware through 8.1.0.0 contains a missing authentication vulnerability that allows remote attackers to read and persistently overwrite device configuration by sending crafted frames to the unauthenticated UDP configuration protocol on port 30718. Attackers can send a type 0xF8 query to read live configuration data and a type 0xFD frame with exactly 0x78 body bytes to rewrite the device IP address and serial-channel forwarding records, causing changes to commit to EEPROM and persist across reboots. The XPress-DR product series reached end-of-life/end-of-support in February 2025.

No affected version ranges are stored yet. Use the vendor advisory before you decide this record does not apply.

How to fix CVE-2026-109439

What to do

Three questions, each answered from this record only. Confirm the vendor advisory before you patch.

Should you patch?

No confirmed exploitation is on record for CVE-2026-109439. EPSS is 0.62%. Act only if a listed version of the affected product is installed.

Which versions are affected?

Affected version ranges are not on this record. Compare the installed version with the linked vendor advisory before you change production.

What should an analyst verify?

CWE-306: Missing Authentication for Critical Function. EPSS 0.62%. There is no CISA KEV listing. No Exploit-DB or Metasploit reference is linked. Use the source links for the original advisory.

Code

The project this record applies to. Exploit listings stay in References.

No public source repository is identified for this product.

Timeline

Detection, updates, and resolution for this record.

  1. Oct 14, 2026 · NIST NVD

    Detected

    Lantronix XPress-DR and XPress-DR-I (CoBos-family) firmware through 8.1.0.0 contains a missing authentication vulnerability that allows remote attackers to read and persistently overwrite device configuration by sending crafted frames to the unauthenticated UDP configuration protocol on port 30718. Attackers can send a type 0xF8 query to read live configuration data and a type 0xFD frame with exac

Sources

  • CVE.orgVulnerability recordCVE-2026-109439

    Official CVE identifier

    cve.org
  • FIRST EPSSExploitation probabilityCVE-2026-109439

    30-day exploitation probability 0.6%

    first.org
  • NIST NVDVulnerability recordCVE-2026-109439

    Lantronix XPress-DR and XPress-DR-I (CoBos-family) firmware through 8.1.0.0 contains a missing authentication vulnerability that allows remote attackers to read and persistently overwrite device configuration by sending crafted frames to the unauthenticated UDP configuration prot