Vulnerability · CVE-2026-24434
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior does not implement CSRF protections for administrative functions in the web management interface.
Published Feb 3, 2026 · catalog updated May 14, 2026 · Shenzhen Tenda Technology Co., Ltd. Tenda AC7
Last checked Nov 5, 2026. A connected source was read within the last 7 days.
Check if you run it
No confirmed exploitation is on record for CVE-2026-24434. EPSS is 0.17%. Act only if a listed version of Shenzhen Tenda Technology Co., Ltd. Tenda AC7 is installed.
Gaps on this record
- No vendor fix or required action is stored. Compare the linked advisory before you change production.
Same product and reporting
- CVE-2026-24441 · High
- CVE-2026-24427 · Medium
- CVE-2026-24426 · Medium
- Severity
- Medium5.1
- Known exploitation
- Not in CISA/VulnCheck KEV
- EPSS
- 0.17%
- Remediation
- Vendor / distro source
- Affected products
- vendor Shenzhen Tenda Technology Co., Ltd. Tenda AC7 0 ≤03.03.03.01_cn
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior does not implement CSRF protections for administrative functions in the web management interface. The interface does not enforce anti-CSRF tokens or robust origin validation, which can allow an attacker to induce a logged-in administrator to perform unintended state-changing requests and modify router settings.
Are you affected?
Enter the version you run. The result uses only the ranges stored on this record.
The check returns affected, not affected, or incomplete. It does not guess a version that is missing from the record.
- vendor Shenzhen Tenda Technology Co., Ltd. Tenda AC7 0 ≤03.03.03.01_cn0 ≤03.03.03.01_cn
How to fix CVE-2026-24434
No stored fix
No vendor fix text is stored. Use the linked advisory before you change production.
Version check
Seen in 0 ≤03.03.03.01_cn
Advisory
Open the cve_org record and follow its fix.
Official advisories
What to do
Three questions, each answered from this record only. Confirm the vendor advisory before you patch.
Should you patch?
No confirmed exploitation is on record for CVE-2026-24434. EPSS is 0.17%. Act only if a listed version of Shenzhen Tenda Technology Co., Ltd. Tenda AC7 is installed.
Which versions are affected?
Compare what you have installed with Shenzhen Tenda Technology Co., Ltd. Tenda AC7 0 ≤03.03.03.01_cn 0 ≤03.03.03.01_cn. Compare the installed version with the linked vendor advisory before you change production.
What should an analyst verify?
No weakness class is stored. EPSS 0.17%. There is no CISA KEV listing. No Exploit-DB or Metasploit reference is linked. Use the source links for the original advisory.
Code
The project this record applies to. Exploit listings stay in References.
No public source repository is identified for this product.
Timeline
Detection, updates, and resolution for this record.
Feb 3, 2026 · EUVD
Detected
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior does not implement CSRF protections for administrative functions in the web management interface. The interface does not enforce anti-CSRF tokens or robust origin validation, which can allow an attacker to induce a logged-in administrator to perform unintended state-changing requests and modify router settings.
May 14, 2026 · EUVD
Updated
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior does not implement CSRF protections for administrative functions in the web management interface. The interface does not enforce anti-CSRF tokens or robust origin validation, which can allow an attacker to induce a logged-in administrator to perform unintended state-changing requests and modify router settings.
Sources
- CVE.orgVulnerability recordCVE-2026-24434
Official CVE identifier
cve.org - FIRST EPSSExploitation probabilityCVE-2026-24434
30-day exploitation probability 0.17%
first.org - EUVDVulnerability recordEUVD-2026-5154
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior does not implement CSRF protections for administrative functions in the web management interface. The interface does not enforce anti-CSRF tokens or robust origin validation, which can allow an attacker to induce a log
euvd.enisa.europa.eu
References
Freshness
Last verified in this catalog Nov 5, 2026. Significant claims (KEV, EPSS, CVSS, affected ranges) come from the source rows above — open the original publisher for the authoritative advisory.
- FIRST EPSSNov 5, 2026
- CVE.orgNov 4, 2026
- EUVDNov 2, 2026