Vulnerability · CVE-2026-2907
A weakness has been identified in Tenda HG9 300001138.
Published Feb 22, 2026 · catalog updated Jun 17, 2026 · hg9 firmware
Check if you run it
No confirmed exploitation is on record for CVE-2026-2907. EPSS is 1.05%. Act only if a listed version of hg9 firmware is installed.
Gaps on this record
- No version range is stored. A customer cannot check an installed version against this record.
- No vendor fix or required action is stored. Compare the linked advisory before you change production.
- Severity
- High7.4
- Known exploitation
- Not in CISA/VulnCheck KEV
- EPSS
- 1.05%
- Remediation
- Advisory link
- Affected products
- cpe tenda/hg9 firmware
A weakness has been identified in Tenda HG9 300001138. Affected by this vulnerability is an unknown functionality of the file /boaform/formgponConf of the component GPON Configuration Endpoint. This manipulation of the argument fmgpon_loid/fmgpon_loid_password causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be used for attacks.
Are you affected?
Enter the version you run. The result uses only the ranges stored on this record.
The check returns affected, not affected, or incomplete. It does not guess a version that is missing from the record.
- cpe tenda/hg9 firmware300001138
How to fix CVE-2026-2907
Recommended remediation
A patch or advisory reference is linked. Open the original publisher for availability by product version.
Official advisories
What to do
Three questions, each answered from this record only. Confirm the vendor advisory before you patch.
Should you patch?
No confirmed exploitation is on record for CVE-2026-2907. EPSS is 1.05%. Act only if a listed version of hg9 firmware is installed.
Which versions are affected?
Compare what you have installed with tenda/hg9 firmware 300001138. Compare the installed version with the linked vendor advisory before you change production.
What should an analyst verify?
CWE-119: Buffer Overflow; CWE-121: Stack-based Buffer Overflow. EPSS 1.05%. There is no CISA KEV listing. No Exploit-DB or Metasploit reference is linked. Use the source links for the original advisory.
Code
The project this record applies to. Exploit listings stay in References.
No public source repository is identified for this product.
Timeline
Detection, updates, and resolution for this record.
Feb 22, 2026 · NIST NVD
Detected
A weakness has been identified in Tenda HG9 300001138. Affected by this vulnerability is an unknown functionality of the file /boaform/formgponConf of the component GPON Configuration Endpoint. This manipulation of the argument fmgpon_loid/fmgpon_loid_password causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made available to the public and co
Jun 17, 2026 · NIST NVD
Updated
A weakness has been identified in Tenda HG9 300001138. Affected by this vulnerability is an unknown functionality of the file /boaform/formgponConf of the component GPON Configuration Endpoint. This manipulation of the argument fmgpon_loid/fmgpon_loid_password causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made available to the public and co
Sources
- CVE.orgVulnerability recordCVE-2026-2907
Official CVE identifier
cve.org - FIRST EPSSExploitation probabilityCVE-2026-2907