Vulnerability · CVE-2026-30956
OneUptime is a solution for monitoring and managing online services.
Published Mar 10, 2026 · catalog updated Oct 7, 2026 · OneUptime is a solution
Check if you run it
No confirmed exploitation is on record for CVE-2026-30956. EPSS is 0.50%. Act only if a listed version of OneUptime is a solution is installed.
Gaps on this record
- The stored product name is a package slug. The name on this page is taken from the title (OneUptime is a solution).
- No vendor fix or required action is stored. Compare the linked advisory before you change production.
- Severity
- Critical9.9
- Known exploitation
- Not in CISA/VulnCheck KEV
- EPSS
- 0.50%
- Remediation
- Version ranges on file
- Affected products
- cpe hackerbay/oneuptime · stated oneuptime
OneUptime is a solution for monitoring and managing online services. Prior to 10.0.21, a low‑privileged user can bypass authorization and tenant isolation in OneUptime v10.0.20 and earlier by sending a forged is-multi-tenant-query header together with a controlled projectid header. Because the server trusts this client-supplied header, internal permission checks in BasePermission are skipped and tenant scoping is disabled. This allows attackers to access project data belonging to other tenants, read sensitive User fields via nested relations, leak plaintext resetPasswordToken, and reset the victim’s password and fully take over the account. This results in cross‑tenant data exposure and full account takeover. This vulnerability is fixed in 10.0.21.
Are you affected?
Enter the version you run. The result uses only the ranges stored on this record.
The check returns affected, not affected, or incomplete. It does not guess a version that is missing from the record.
- cpe hackerbay/oneuptimeversion unspecified
- stated oneuptime<= 0.20
How to fix CVE-2026-30956
Recommended remediation
Affected version ranges suggest a fixed boundary. Verify against the vendor advisory for your release.
Official advisories
What to do
Three questions, each answered from this record only. Confirm the vendor advisory before you patch.
Should you patch?
No confirmed exploitation is on record for CVE-2026-30956. EPSS is 0.50%. Act only if a listed version of OneUptime is a solution is installed.
Which versions are affected?
Compare what you have installed with <= 0.20. Compare the installed version with the linked vendor advisory before you change production.
What should an analyst verify?
CWE-285: Improper Authorization; CWE-862: Missing Authorization. EPSS 0.50%. There is no CISA KEV listing. No Exploit-DB or Metasploit reference is linked. Use the source links for the original advisory.
Code
The project this record applies to. Exploit listings stay in References.
Timeline
Detection, updates, and resolution for this record.
Mar 10, 2026 · NIST NVD
Detected
OneUptime is a solution for monitoring and managing online services. Prior to 10.0.21, a low‑privileged user can bypass authorization and tenant isolation in OneUptime v10.0.20 and earlier by sending a forged is-multi-tenant-query header together with a controlled projectid header. Because the server trusts this client-supplied header, internal permission checks in BasePermission are skipped and t
Oct 7, 2026 · NIST NVD
Updated
OneUptime is a solution for monitoring and managing online services. Prior to 10.0.21, a low‑privileged user can bypass authorization and tenant isolation in OneUptime v10.0.20 and earlier by sending a forged is-multi-tenant-query header together with a controlled projectid header. Because the server trusts this client-supplied header, internal permission checks in BasePermission are skipped and t
Sources
- CVE.orgVulnerability recordCVE-2026-30956
Official CVE identifier
cve.org - FIRST EPSSExploitation probabilityCVE-2026-30956
30-day exploitation probability 0.5%
first.org - NIST NVDVulnerability recordCVE-2026-30956
OneUptime is a solution for monitoring and managing online services. Prior to 10.0.21, a low‑privileged user can bypass authorization and tenant isolation in OneUptime v10.0.20 and earlier by sending a forged is-multi-tenant-query header together with a controlled projectid heade
nvd.nist.gov
References
Freshness
Last verified in this catalog Oct 18, 2026. Significant claims (KEV, EPSS, CVSS, affected ranges) come from the source rows above — open the original publisher for the authoritative advisory.