Vulnerability · CVE-2026-5944
An improper access control vulnerability exists in the Cisco Intersight Device Connector for Nutanix Prism Central.
Published Apr 28, 2026 · catalog updated Jun 17, 2026 · intersight device connector
Check if you run it
No confirmed exploitation is on record for CVE-2026-5944. EPSS is 0.91%. Act only if a listed version of intersight device connector is installed.
Gaps on this record
- No version range is stored. A customer cannot check an installed version against this record.
- No vendor fix or required action is stored. Compare the linked advisory before you change production.
- Severity
- Medium6.7
- Known exploitation
- Not in CISA/VulnCheck KEV
- EPSS
- 0.91%
- Remediation
- Advisory link
- Affected products
- cpe cisco/intersight device connector
An improper access control vulnerability exists in the Cisco Intersight Device Connector for Nutanix Prism Central. The service exposes an API passthrough endpoint on TCP port 7373 that is accessible within the network scope of the deployment environment without authentication. An unauthenticated attacker with network access can exploit this vulnerability by sending crafted requests to the exposed endpoint to enumerate cluster metadata, including virtual machine information and cluster configuration details. While the API primarily supports read-only operations, it also allows certain cluster maintenance workflows to be invoked. Although this vulnerability does not allow persistent modification of system configurations or access to credentials or sensitive user data, successful exploitation may result in disruption of active workloads, leading to loss of service availability within the affected environment.
Are you affected?
Enter the version you run. The result uses only the ranges stored on this record.
The check returns affected, not affected, or incomplete. It does not guess a version that is missing from the record.
- cpe cisco/intersight device connectorversion unspecified
How to fix CVE-2026-5944
Recommended remediation
A patch or advisory reference is linked. Open the original publisher for availability by product version.
Official advisories
What to do
Three questions, each answered from this record only. Confirm the vendor advisory before you patch.
Should you patch?
No confirmed exploitation is on record for CVE-2026-5944. EPSS is 0.91%. Act only if a listed version of intersight device connector is installed.
Which versions are affected?
Affected version ranges are not on this record. Compare the installed version with the linked vendor advisory before you change production.
What should an analyst verify?
CWE-306: Missing Authentication for Critical Function; CWE-862: Missing Authorization. EPSS 0.91%. There is no CISA KEV listing. No Exploit-DB or Metasploit reference is linked. Use the source links for the original advisory.
Technology hubs
Code
The project this record applies to. Exploit listings stay in References.
No public source repository is identified for this product.
Timeline
Detection, updates, and resolution for this record.
Apr 28, 2026 · NIST NVD
Detected
An improper access control vulnerability exists in the Cisco Intersight Device Connector for Nutanix Prism Central. The service exposes an API passthrough endpoint on TCP port 7373 that is accessible within the network scope of the deployment environment without authentication. An unauthenticated attacker with network access can exploit this vulnerability by sending crafted requests to the exposed
Jun 17, 2026 · NIST NVD
Updated
An improper access control vulnerability exists in the Cisco Intersight Device Connector for Nutanix Prism Central. The service exposes an API passthrough endpoint on TCP port 7373 that is accessible within the network scope of the deployment environment without authentication. An unauthenticated attacker with network access can exploit this vulnerability by sending crafted requests to the exposed
Sources
- CVE.orgVulnerability recordCVE-2026-5944
Official CVE identifier
cve.org - FIRST EPSSExploitation probabilityCVE-2026-5944
30-day exploitation probability 0.9%
first.org - NIST NVDVulnerability recordCVE-2026-5944
An improper access control vulnerability exists in the Cisco Intersight Device Connector for Nutanix Prism Central. The service exposes an API passthrough endpoint on TCP port 7373 that is accessible within the network scope of the deployment environment without authentication.
nvd.nist.gov
References
Freshness
Last verified in this catalog Oct 18, 2026. Significant claims (KEV, EPSS, CVSS, affected ranges) come from the source rows above — open the original publisher for the authoritative advisory.