Vulnerabilities

Vulnerability · CVE-2026-68472

In the Linux kernel, the following vulnerability has been resolved: wifi: cfg80211: validate EHT MLE before MLD ID read cfg80211_gen_new_ie() copies ML probe response…

Published Aug 15, 2026 · catalog updated Oct 19, 2026 · the affected product

Open the advisory

Exploitation likelihood is not on this record for CVE-2026-68472. A missing EPSS score is not a low risk. Compare the affected product with the linked advisory before you change production.

Gaps on this record

  • No plain product name is stored. The page cannot tell you which product to check.
  • No version range is stored. A customer cannot check an installed version against this record.
  • No vendor fix or required action is stored. Compare the linked advisory before you change production.
  • EPSS is missing. A missing score is not a low risk.
Severity
High8.1
Known exploitation
Not in CISA/VulnCheck KEV
EPSS
Awaiting synchronization with FIRST
Remediation
Not established
Affected products
See sources for product scope

In the Linux kernel, the following vulnerability has been resolved: wifi: cfg80211: validate EHT MLE before MLD ID read cfg80211_gen_new_ie() copies ML probe response elements from the parent frame when the parent EHT multi-link element has an MLD ID matching the nontransmitted BSSID index. The code only checked that the extension element had more than one byte before calling ieee80211_mle_get_mld_id(). That helper assumes a BASIC MLE with enough common info and documents that callers must first use ieee80211_mle_type_ok(). Attack chain: malicious AP sends a short EHT MLE in an MBSSID beacon. cfg80211_inform_bss_frame_data() stores the copied IE buffer. cfg80211_parse_mbssid_data() builds the nontransmitted BSS IE. cfg80211_gen_new_ie() sees the EHT MLE in the parent frame. ieee80211_mle_get_mld_id() then reads past the IE boundary. Validate the MLE type and size before reading the MLD ID. This matches the contract required by the MLE helper and rejects the short element before any internal MLE fields are accessed.

No affected version ranges are stored yet. Use the vendor advisory before you decide this record does not apply.

How to fix CVE-2026-68472

  • Recommended remediation

    No required-action text, fix commit, or clear fixed-version range is stored yet.

  • Official advisories

What to do

Three questions, each answered from this record only. Confirm the vendor advisory before you patch.

Should you patch?

Exploitation likelihood is not on this record for CVE-2026-68472. A missing EPSS score is not a low risk. Compare the affected product with the linked advisory before you change production.

Which versions are affected?

Affected version ranges are not on this record. Compare the installed version with the linked vendor advisory before you change production.

What should an analyst verify?

CWE-125: Out-of-bounds Read. EPSS is not on this record yet. There is no CISA KEV listing. No Exploit-DB or Metasploit reference is linked. Use the source links for the original advisory.

Code

The project this record applies to. Exploit listings stay in References.

Timeline

Detection, updates, and resolution for this record.

  1. Aug 15, 2026 · NIST NVD

    Detected

    In the Linux kernel, the following vulnerability has been resolved: wifi: cfg80211: validate EHT MLE before MLD ID read cfg80211_gen_new_ie() copies ML probe response elements from the parent frame when the parent EHT multi-link element has an MLD ID matching the nontransmitted BSSID index. The code only checked that the extension element had more than one byte before calling ieee80211_mle_get_mld

  2. Oct 19, 2026 · NIST NVD

    Updated

    In the Linux kernel, the following vulnerability has been resolved: wifi: cfg80211: validate EHT MLE before MLD ID read cfg80211_gen_new_ie() copies ML probe response elements from the parent frame when the parent EHT multi-link element has an MLD ID matching the nontransmitted BSSID index. The code only checked that the extension element had more than one byte before calling ieee80211_mle_get_mld

Sources

  • NIST NVDVulnerability recordCVE-2026-68472

    In the Linux kernel, the following vulnerability has been resolved: wifi: cfg80211: validate EHT MLE before MLD ID read cfg80211_gen_new_ie() copies ML probe response elements from the parent frame when the parent EHT multi-link element has an MLD ID matching the nontransmitted

    nvd.nist.gov

References

Freshness

Last verified in this catalog Oct 19, 2026. Significant claims (KEV, EPSS, CVSS, affected ranges) come from the source rows above — open the original publisher for the authoritative advisory.