Vulnerabilities

Vulnerability · CVE-2026-89932

KVM: nVMX: Always flush vpid02 on first use

Published Sep 16, 2026 · catalog updated Oct 16, 2026 · KVM: nVMX: Always flush

Check if you run it

No confirmed exploitation is on record for CVE-2026-89932. EPSS is 0.16%. Act only if a listed version of KVM: nVMX: Always flush is installed.

Gaps on this record

  • The stored product name is a package slug. The name on this page is taken from the title (KVM: nVMX: Always flush).
  • No vendor fix or required action is stored. Compare the linked advisory before you change production.
Severity
High8.8
Known exploitation
Not in CISA/VulnCheck KEV
EPSS
0.16%
Remediation
Advisory link
Affected products
Linux Kernel

In the Linux kernel, the following vulnerability has been resolved: KVM: nVMX: Always flush vpid02 on first use Make sure vpid02 is always flushed on first use by setting last_vpid=0 when allocating vpid02. nested_vmx_transition_tlb_flush() will always detect a VPID change on first VM-Enter after VMXON, because VPID=0 in vmcs12 is not allowed if L1 enables VPID. This avoids using stale TLB entries from a previous lifetime of the VPID, that might have been associated with a different vCPU (or a completely different VM). Note that last_vpid is already being initialized as 0 when the vCPU is created, but it is not reset when vpid02 is freed on VMXOFF. Hence, the problem can only occur if L1 does VMXOFF -> VMXON, runs an L2, and KVM happens to reuse a VPID that has TLB entries on the physical CPU.

Are you affected?

Enter the version you run. The result uses only the ranges stored on this record.

The check returns affected, not affected, or incomplete. It does not guess a version that is missing from the record.

  • Linux Kernel4.4.0 → 5.15.221

How to fix CVE-2026-89932

What to do

Three questions, each answered from this record only. Confirm the vendor advisory before you patch.

Should you patch?

No confirmed exploitation is on record for CVE-2026-89932. EPSS is 0.16%. Act only if a listed version of KVM: nVMX: Always flush is installed.

Which versions are affected?

Compare what you have installed with Kernel 4.4.0 → 5.15.221. Compare the installed version with the linked vendor advisory before you change production.

What should an analyst verify?

No weakness class is stored. EPSS 0.16%. There is no CISA KEV listing. No Exploit-DB or Metasploit reference is linked. Use the source links for the original advisory.

Code

The project this record applies to. Exploit listings stay in References.

Timeline

Detection, updates, and resolution for this record.

  1. Sep 16, 2026 · OpenSSF OSV / OSV Scanner

    Detected

    In the Linux kernel, the following vulnerability has been resolved: KVM: nVMX: Always flush vpid02 on first use Make sure vpid02 is always flushed on first use by setting last_vpid=0 when allocating vpid02. nested_vmx_transition_tlb_flush() will always detect a VPID change on first VM-Enter after VMXON, because VPID=0 in vmcs12 is not allowed if L1 enables VPID. This avoids using stale TLB entries

  2. Oct 16, 2026 · OpenSSF OSV / OSV Scanner

    Fix available

    Kernel fixed in 5.15.221

  3. Oct 16, 2026 · OpenSSF OSV / OSV Scanner

    Fix available

    Kernel fixed in 5.15.221

  4. Oct 16, 2026 · OpenSSF OSV / OSV Scanner

    Updated

    In the Linux kernel, the following vulnerability has been resolved: KVM: nVMX: Always flush vpid02 on first use Make sure vpid02 is always flushed on first use by setting last_vpid=0 when allocating vpid02. nested_vmx_transition_tlb_flush() will always detect a VPID change on first VM-Enter after VMXON, because VPID=0 in vmcs12 is not allowed if L1 enables VPID. This avoids using stale TLB entries

Sources

References

Freshness

Last verified in this catalog Oct 18, 2026. Significant claims (KEV, EPSS, CVSS, affected ranges) come from the source rows above — open the original publisher for the authoritative advisory.